MDS with PNH clone (2)

About this case study
Details:

MDS with PNH clone (2)

Flow cytometry
Details of flow cytometry instrument

BD FACSCanto

Cell populations evaluated for PNH clones:

Granulocytes, monocytes, RBCs

External control:

None

Internal control:

None

Antibodies/reagents and gating strategies used:

FLAER-Alexa 488, CD14 (61D3)-PE, CD15 (H198)-APC, CD24 (SN3)-PE, CD64 (10.1)-PE, CD45 (2D1)-PerCP-Cy5.5, CD59 (MEM43)-PE, CD235a (KC16)-FITC Practical Guidelines 2012

Clone sizes in all populations tested:

Granulocytes: 66.2% (Type II + III)
Monocytes: 76.9% (Type II + III)
RBCs: 14.9% (Type III), 0.3% (Type II)

LDH level:8.7 µkat/L (2.2–3.6)
Ferritin level:3050 µg/L (10–291)
Creatine level:108 µmol/L (44–104)
RBC count:2.38 x 1012/L (3.90–5.20)
WBC and neutrophil counts:5.0 x 109/L (4.00–10.80)
Platelet count:106.00 x 109/L (150.00–400.00)
FLAER, fluorescent aerolysin; LDH, lactate dehydrogenase; MDS, myelodysplastic syndrome; RBC, red blood cell; WBC, white blood cell

Netflow - MDS with PNH clone (2)

FC data

Netflow - MDS with PNH clone (2)

Dot plots


aAll case study files are provided with permission from the Steering Committee and other registered users of the website and are for personal use only, not for distribution